IO302 data sheet

General

  • Form factor: 32-bit 33MHz PMC (PCI)
  • Standard operating temperature: 0ºC to +70ºC
  • Extended operating temperature: -40ºC to +85ºC
  • Humidity: 5 to 95%, non-condensing
  • Power consumption: 7.5W max

Digital

  • Transceiver type: RS422 (differential)
  • Number of I/O lines: 32
  • Direction: I/O lines individually programmable as inputs or outputs
  • Differential driver output voltage with 50Ohm load: 2V minimum, 5V maximum
  • Common mode output voltage: 3V maximum
  • Differential input threshold voltage (-7V<=VCM<=12V): VCM= -0.2V minimum, 0.2V maximum
  • Input Hysteresis: 70mV typical
  • Minimum input resistance: 12kOhm
  • Fail-safe: The receiver contains a fail-safe feature that results in a logic high output state if the inputs are unconnected (floating).
  • Termination resistors: 120Ohm termination resistor networks are installed in sockets. Networks of 4 resistors each are used for the differential signals.